BinMaster Level Control Product Specifications - PRO Auto-Cal

BinMaster product sheet: Capacitance: PRO Auto-Cal


PRO Auto-Cal simple and automatic calibration and testing without having to remove the cover. Calibration takes just seconds and is performed with the use of a special magnet.

Features
  • Auto-Calibration and external test
  • Unsurpassed sensitivity 0.5 pF 
  • PRO-Shield compensates for  material build-up
  • Operates below RF range, temperature stable calibration and protection from RF interference
  • Fail-Safe, switch selectable high/low
  • Adjustable time delay to 10 seconds
  • Optional sensing probes: Delrin or Teflon sleeved, bare, food grade, flush  mount, solid and flexible extension
  • Visual LED indicates sensor status: uncovered, covered or power failure
Specifications: PRO Auto-Cal
Power Requirements: 115/230 VAC
50/60 Hz ± 15%, 5VA
Output Relay: DPDT 10 Amp at 250 VAC
STATUS Contacts: 3 Amps 240 VAC
Ambient Temperature
Electronics:
Probe:
-40° to +185°F (-40° to +85°C)
+250°F Delrin, +500°F Teflon
Pressure: 500 PSI, ¾" Mount
Sensitivity Setting: Adjustable Sensitivity to < 1 Picofarad
Calibration: "Quick Set" Course/Fine
Single Turn Potentiometers
Fail-Safe: Switch Selectable High/Low
Time Delay: Adjust .25 to 10 Seconds
Enclosure
Probe:

Electronics:
Cast Aluminum, Bolt-on Cover
USDA Approved Finish
Plastic
Mounting: 1 ¼" NPT or ¾" NPT 316 SS
Pro Shield: Compensates For Material Build-up On Sensing Probe
Approval Ratings
Probe:
C/US listed for Class II, Groups E, F, G. Enclosure type NEMA 4X, 5, 9 &12
Status Indicator: Internal LED Indicates Material
In Contact With Probe
Probe Options: Delrin, Teflon, Food Grade, Flush Mount, Flexible Extension, Stubby Shielded, Extended Shielded, Bare Shielded and Lagged